Medical cable
Hwatek
M0090190
Endoscope Medical Cable
Product Description:
Cable Specification | Conductor | Insulation | Insulation Dia.(mm) | Jacket | Outer Dia. (mm) | Voltage rating | Rated Temperature | ||||
Number of conductors | AWG | Conductor cross section | Construction | Diameter | |||||||
4*44AWG+6*42AWG | 10 | 44 | 0.22 | 7/0.20 | 0.61 | PFA | 0.156 | FEP | 1.5 | 30V | 80°C |
Advantages:
Good anti-interference ability
clear and stable image transmission
small diameter
flexible
Application:Various endoscope image transmission .
Technical Parameter:
Rated temperature: 80ºC
Rated Voltage: 30V
ELECTRICAL CHARACTERISTICS:
Rated voltage:30V |
Rated temperature:80℃ |
Max. DC conductor resistance(20℃):44AWG:10,500Ω/km; 42AWG:7,500Ω/km |
Voltage withstand test:AC 500V/1min |
Characteristic impedance (at 10MHz): 44AWG coaxial: 50±5Ω/m |
Allowable current(Ref.)*: 42AWG Wire:300mA |
Note*:wire in the air, at ambient temperature 40℃, max.conductor temperature 80℃. |
A medical endoscope is a medical device consisting of a bendable part, a light source and a set of lenses. The endoscope enters the human body through the natural orifice of the human body, or through a small incision made by surgery. When in use, the endoscope is introduced into the pre-examined organ, and the changes in the relevant parts can be directly observed. The quality of the image directly affects the use effect of the endoscope。
What is an endoscope connector?
The connector section connects the endoscope with the video system center through the universal cord. Supply of air and water is also performed through this connection.
Endoscope Medical Cable
Product Description:
Cable Specification | Conductor | Insulation | Insulation Dia.(mm) | Jacket | Outer Dia. (mm) | Voltage rating | Rated Temperature | ||||
Number of conductors | AWG | Conductor cross section | Construction | Diameter | |||||||
4*44AWG+6*42AWG | 10 | 44 | 0.22 | 7/0.20 | 0.61 | PFA | 0.156 | FEP | 1.5 | 30V | 80°C |
Advantages:
Good anti-interference ability
clear and stable image transmission
small diameter
flexible
Application:Various endoscope image transmission .
Technical Parameter:
Rated temperature: 80ºC
Rated Voltage: 30V
ELECTRICAL CHARACTERISTICS:
Rated voltage:30V |
Rated temperature:80℃ |
Max. DC conductor resistance(20℃):44AWG:10,500Ω/km; 42AWG:7,500Ω/km |
Voltage withstand test:AC 500V/1min |
Characteristic impedance (at 10MHz): 44AWG coaxial: 50±5Ω/m |
Allowable current(Ref.)*: 42AWG Wire:300mA |
Note*:wire in the air, at ambient temperature 40℃, max.conductor temperature 80℃. |
A medical endoscope is a medical device consisting of a bendable part, a light source and a set of lenses. The endoscope enters the human body through the natural orifice of the human body, or through a small incision made by surgery. When in use, the endoscope is introduced into the pre-examined organ, and the changes in the relevant parts can be directly observed. The quality of the image directly affects the use effect of the endoscope。
What is an endoscope connector?
The connector section connects the endoscope with the video system center through the universal cord. Supply of air and water is also performed through this connection.