Color: | |
---|---|
Rated voltage: | |
Rated temperature: | |
Availability: | |
Quantity: | |
TC-ER
Hwatek
HT1501560
Electric Power TC-ER Cable
Product Description:
SPECIFICATION | CABLE NAME | TC-ER | |||
CABLE SPEC | 4C×1AWG+1C×6AWG | ||||
RoHS Compliant | |||||
ITEM | A : 4C×1AWG | B : 1C×6AWG | |||
CONDUCTOR | Material | Tinned copper stranded(Class K,ASTM B 172) | Tinned copper stranded(Class K,ASTM B 172) | ||
Size | 827/0.254±0.008mm | 266/0.254±0.008mm | |||
O.D.(Ref) | 9.20mm | 5.00mm | |||
INSULATION | Material | PVC(Flame retardant:VW-1) | PVC(Flame retardant:VW-1) | ||
Min.average thickness | 1.27mm | 0.76mm | |||
Min.thickness at any point | 1.14mm | 0.69mm | |||
O.D. | 12.14±0.40mm | 6.88±0.30mm | |||
COVERING | Material | Nylon | Nylon | ||
Min.thickness at any point | 0.20mm | 0.13mm | |||
O.D. | 12.60±0.40mm | 7.30±0.30mm | |||
CABLING | Fillers | PP rope | |||
Material | Polyester tape | ||||
Assembly | 4C×1AWG+1C×6AWG | ||||
BRAID | Material | Tinned copper | |||
Size | 0.20mm,Coverage :85%min. | ||||
Pitch.(Ref) | Ensure the density, the pitch is as small as possible, according to the actual situation of adjustment | ||||
WRAPED | Material | AL-mylar(Foil face in,55μ) | |||
JACKET | Material | PVC(Flame retardant:94V0) | |||
Min.average thickness | 2.03mm | ||||
Min.thickness at any point | 1.63mm | ||||
O.D. | 37.00±2.00mm | ||||
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:AC 600 or 1000V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:-40~90ºC | Elongation: | ≥100% | |||
Max. DC conductor resistance(20ºC): | Aged condition: | 121±1ºC×168h | |||
A:0.467Ω/km B:1.403Ω/km | Percent of original tensile strength: | ≥70% | |||
Voltage withstand test:AC 2.0kV/1min | Percent of original elongation: | ≥65% | |||
Flame test : | FT4 | ||||
Min. bending radius : 9 inch.(fixed installation) |
Electric Power TC-ER Cable
Product Description:
SPECIFICATION | CABLE NAME | TC-ER | |||
CABLE SPEC | 4C×1AWG+1C×6AWG | ||||
RoHS Compliant | |||||
ITEM | A : 4C×1AWG | B : 1C×6AWG | |||
CONDUCTOR | Material | Tinned copper stranded(Class K,ASTM B 172) | Tinned copper stranded(Class K,ASTM B 172) | ||
Size | 827/0.254±0.008mm | 266/0.254±0.008mm | |||
O.D.(Ref) | 9.20mm | 5.00mm | |||
INSULATION | Material | PVC(Flame retardant:VW-1) | PVC(Flame retardant:VW-1) | ||
Min.average thickness | 1.27mm | 0.76mm | |||
Min.thickness at any point | 1.14mm | 0.69mm | |||
O.D. | 12.14±0.40mm | 6.88±0.30mm | |||
COVERING | Material | Nylon | Nylon | ||
Min.thickness at any point | 0.20mm | 0.13mm | |||
O.D. | 12.60±0.40mm | 7.30±0.30mm | |||
CABLING | Fillers | PP rope | |||
Material | Polyester tape | ||||
Assembly | 4C×1AWG+1C×6AWG | ||||
BRAID | Material | Tinned copper | |||
Size | 0.20mm,Coverage :85%min. | ||||
Pitch.(Ref) | Ensure the density, the pitch is as small as possible, according to the actual situation of adjustment | ||||
WRAPED | Material | AL-mylar(Foil face in,55μ) | |||
JACKET | Material | PVC(Flame retardant:94V0) | |||
Min.average thickness | 2.03mm | ||||
Min.thickness at any point | 1.63mm | ||||
O.D. | 37.00±2.00mm | ||||
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:AC 600 or 1000V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:-40~90ºC | Elongation: | ≥100% | |||
Max. DC conductor resistance(20ºC): | Aged condition: | 121±1ºC×168h | |||
A:0.467Ω/km B:1.403Ω/km | Percent of original tensile strength: | ≥70% | |||
Voltage withstand test:AC 2.0kV/1min | Percent of original elongation: | ≥65% | |||
Flame test : | FT4 | ||||
Min. bending radius : 9 inch.(fixed installation) |