Color: | |
---|---|
Rated voltage: | |
Rated temperature: | |
Availability: | |
Quantity: | |
Industrial Cable
Hwatek
HT1805463
Product Description:
SPECIFICATION | CABLE NAME | UL2464&CL2 | |||
CABLE SPEC | 12P×22AWG+1C×22AWG | ||||
RoHS Compliant | |||||
ITEM | A : 12P×22AWG | B : 1C×22AWG | |||
CONDUCTOR | Material | Tinned copper stranded | |||
Size | 7/0.254mm | 7/0.254mm | |||
O.D.(Ref) | 0.76mm | 0.76mm | |||
INSULATION | Material | SR-PVC | SR-PVC | ||
Min.average thickness | 0.23mm | 0.23mm | |||
Min.thickness at any point | 0.18mm | 0.18mm | |||
O.D. | 1.30±0.05mm | 1.30±0.05mm | |||
TWISTED | O.D.(Ref) | 2.60mm | / | ||
CABLING | Filler | PP rope | |||
Material | Al-mylar(foil face out) | ||||
Assembly | 12P×22AWG+1C×22AWG | ||||
BRAID | Material | Tinned copper | |||
Size | 24/12/0.12mm(90% Nom.) | ||||
JACKET | Material | PVC(Shore:81±3A) | |||
Min.average thickness | 0.84mm | ||||
Min.thickness at any point | 0.66mm | ||||
O.D. | 12.50±0.30mm | ||||
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:300V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:80ºC | Elongation: | ≥100% | |||
Max. DC conductor resistance(20ºC):59.4Ω/km | Aged condition: | 113±1ºC×168h | |||
Voltage withstand test:AC 2.0kV/1min | Percent of original tensile strength: | ≥70% | |||
Percent of original elongation: | ≥65% | ||||
Deformation(121±2ºC*1h,2kg): | ≤50% | ||||
Cold bend test(-20±2ºC*4h): | No crack | ||||
Heat shock test(121±2ºC*1h): | No crack |
What is fire proof cable?
Flame retardant cables are designed to resist the spread of fire into a new area. Fire resistant cables are designed to maintain circuit integrity and continue to work for a specified period of time under defined conditions.
Product Description:
SPECIFICATION | CABLE NAME | UL2464&CL2 | |||
CABLE SPEC | 12P×22AWG+1C×22AWG | ||||
RoHS Compliant | |||||
ITEM | A : 12P×22AWG | B : 1C×22AWG | |||
CONDUCTOR | Material | Tinned copper stranded | |||
Size | 7/0.254mm | 7/0.254mm | |||
O.D.(Ref) | 0.76mm | 0.76mm | |||
INSULATION | Material | SR-PVC | SR-PVC | ||
Min.average thickness | 0.23mm | 0.23mm | |||
Min.thickness at any point | 0.18mm | 0.18mm | |||
O.D. | 1.30±0.05mm | 1.30±0.05mm | |||
TWISTED | O.D.(Ref) | 2.60mm | / | ||
CABLING | Filler | PP rope | |||
Material | Al-mylar(foil face out) | ||||
Assembly | 12P×22AWG+1C×22AWG | ||||
BRAID | Material | Tinned copper | |||
Size | 24/12/0.12mm(90% Nom.) | ||||
JACKET | Material | PVC(Shore:81±3A) | |||
Min.average thickness | 0.84mm | ||||
Min.thickness at any point | 0.66mm | ||||
O.D. | 12.50±0.30mm | ||||
ELECTRICAL CHARACTERISTICS | PHYSICAL PROPERTIES | ||||
Rated voltage:300V | Tensile strength: | ≥10.3MPa | |||
Rated temperature:80ºC | Elongation: | ≥100% | |||
Max. DC conductor resistance(20ºC):59.4Ω/km | Aged condition: | 113±1ºC×168h | |||
Voltage withstand test:AC 2.0kV/1min | Percent of original tensile strength: | ≥70% | |||
Percent of original elongation: | ≥65% | ||||
Deformation(121±2ºC*1h,2kg): | ≤50% | ||||
Cold bend test(-20±2ºC*4h): | No crack | ||||
Heat shock test(121±2ºC*1h): | No crack |